Xindun DA Solar Inverter Chargers: 4000W-7000W
search
  • Xindun DA Solar Inverter Chargers: 4000W-7000W
  • Xindun DA Solar Inverter Chargers: 4000W-7000W
  • Xindun DA Solar Inverter Chargers: 4000W-7000W
  • Xindun DA Solar Inverter Chargers: 4000W-7000W
  • Xindun DA Solar Inverter Chargers: 4000W-7000W

Xindun Solar Inverter Chargers

£200.00
No tax 7-10 days

Xindun DA Solar Inverter Chargers - available in various versions: 4000W-7000W 24V/48V - 4000W/5000W/6000W/7000W DC24V/48V to AC110V/120V/220V/230V/240V | Pure Sine Wave Inverters | Motorhome Inverter Chargers -  DC to AC Off-Grid Inverters

 

Specifications: 4000W Inverter Charger
Quantity

1 EI low frequency transformer, pure sine wave inverter output, strong impact resistance;

2 Dedicated micro-processing chip design, equipment operation speed is faster and more stable;

3 LCD display,real-time view of setting parameters and operating status;

4 AC charging current 0~30A adjustable,battery configurations are more flexible by users;

5 Three working modes(AC first,battery first,energy-saving mode);

6 Equipped with stable voltage and frequency output, stronger load compatibility;

7 Perfect all-round automatic protection function, stable and reliable performance;

8 Perfect fault code query function, convenient for users to monitor the running status in real time;

9 Support diesel or petrol generators, adapt to any tough electricity environment;

10 Motorhome inverter charger with RS485 communication port/APP (WIFI or GPRS) optional.

Motorhome Inverter Charger Specification


Specification
Model DA 40224/48 50248 60248 70248
Rated Power 4000W 5000W 6000W 7000W
Peak Power(20ms) 12000VA 15000VA 18000VA 21000VA
Start Motor 3HP 4HP 4HP 5HP
Battery Voltage 24/48VDC 48VDC
Size(L*W*Hmm) 525*292*206
Packing Size(L*W*Hmm) 620*340*265
N.W.(kg) 40 43 46 48
G.W.(kg)(Carton Packing) 43 46 49 51
Installation Method Wall-Mounted
Parameter
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range 85VAC~138VAC(110VAC) / 95VAC~148VAC(120VAC) / 170VAC~275VAC(220VAC) /
180VAC~285VAC(230VAC) / 190VAC~295VAC(240VAC)
AC Input Frequency Range 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current 0~30A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
Output Frequency(Battery Mode) 50/60Hz±1%
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Output Frequency(AC Mode) Tracking Automatically
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤2.5% rated power
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss(Energy saving Mode) ≤10W
Battery Type VRLA Battery Charge Voltage :14.2V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm Factory default: 11V(12V system; 24V system x2; 48V system x4)
Battery undervoltage protection Factory default: 10.5V(12V system; 24V system x2; 48V system x4)
Battery overvoltage alarm Factory default: 15V(12V system; 24V system x2; 48V system x4)
Battery overvoltage protection Factory default: 17V(12V system; 24V system x2; 48V system x4)
Battery overvoltage recovery voltage Factory default: 14.5V(12V system; 24V system x2; 48V system x4)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Cooling fan in intelligent control
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise ≤55dB
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation
Note: All specifications are subject to charge without prior notice
Xindun
Xindun DA Inverter Charger
100 Items

You might also like

Comments (0)
No customer reviews for the moment.