- New
TTnergy Hyson Solar Hybrid Inverters
TTnergy Hyson Single Phase Hybrid Inverters - 220V/50Hz, 2-4MPPT - available in various versions: 6KW-8KW-10KW-12KW. A WiFi and monitoring app is available to allow the user to monitor the system 24hrs remotely.
FEATURES
AC Coupling to retrofit existing solar systems
Max 16pcs parallel for on-grid and off-grid operations; support multiple batteries parallel
Max charging/discharging current of 135A
6 time periods for battery charging/discharging
Support storing energy from diesel generator
IP65 protection degree
PROPERTIES - 6KW Version
PV String Input Data
Max. Dc Input Power(W) - 7800
Rated PV Input Voltage (V) - 370(125-500)
Star-up Voltage(V) - 125
MPPT Voltage Range(V): 150-425
Full Load MPPT Voltage Range(V)
Max. DC Input Current(A) - 13+13
Max. PV Isc(A) - 22+22
No. of MPPT Trackers - 2
No. of Strings per MPPT Tracker - 1+1
AC Input/Output Data
Rated AC Output Power(W) - 6000
Max AC Output Power(W) - 6600
AC Input/Output Rated Current(A) - 27.3/26.1
Max. AC Input/Output Current(A)- 30/28.7
Max. Continuous AC Passthrough(A) - 40
Peak Power(off grid) - 2 times of rated power, 10.5
Power Factor: 0.8 leading - 0.8 lagging
AC Output Frequency and Voltage - 50/60Hz: 220/230VAC
Grid Type - Single Phase
Total Harmonic Distortion(THDi):<3% (of nominal power)
DC Current Injection: <0.5% (Rated Current)
Battery Input Data
Battery Type - Lead acid or Lithium-ion
Battery Voltage Range(V): 40-60
Max. Charging Current(A) - 135
Max. Discharging Current - 135
External Temperature Sensor - Yes
Charging Curve - 3 Stages/Equalization
Charging Strategy for Li-Ion Battery - Self-adaptation to BMS
Efficiency
Max. Efficiency - 97.6%
Euro Efficiency - 96.50%
MPPT Efficiency - 99%
Protection
Anti-islanding Protection - Integrated
PV String Input Reverse Polarity Protection - Integrated
Insulation Resistor Detection - Integrated
Residual Current Monitoring Unit - Integrated
Output Over Current Protection - Integrated
Output Shorted Protection - Integrated
Surge Protection - DC Type II/AC Type II
Over Voltage Category - DC Type II/AC Type III
Certifications and Standards
Grid Regulation - IEC61727/IEC 62116, EN 50549-1
Safety EMC/Standard - IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range(C): -40-60C, >45C Derating
Cooling - Smart Cooling
Noise(dB) - <_50 dB
Communication with BMS - RS485:CAN
Monitoring mode - WIFI, APP
Weight - 24kg
Size - 346X506X355mm
Protection Degree - IP65
Installation Style - Wall mounted
Warranty - 5yrs(10yrs optional)