- New
Xindun Hybrid Solar Inverters
WDT Solar Panel Power Inverters - DC to AC Off Grid Inverters, with 10A-120A PWM/MPPT Charge Controller. Available in various versions - 4KW, 5kW, 6KW, and 7KW versions
7KW Inverter Features -
7KW/96VDC/MPPT 50A;
AC output voltage: 220V/50Hz;
Toroidal transformer lower loss;
Single phase, pure sine wave output;
Transfer time ≤4ms;
LCD display, floor mounted design;
RS485 communication port;
With Inbuilt MPPT controller :50A;
PV Array Maximum Power: 5600W
PRODUCT PARAMETERS
Solar panel power inverter built-in PWM or MPPT controller optional;
Pure sine wave output;
High efficiency toroidal transformer lower loss ;
Intelligent LCD integration display;
AC charge current 0-20A adjustable; battery capacity configuration more flexible;
Three types working modes adjustable:AC first, DC first, energy-saving mode;
Frequency adaptive function, adapt to different grid environments;
Added fault code query function,facilitate user to monitor the operation state in real time;
Supports diesel or gasoline generator, adapt any tough electricity situation;
RS485 communication port/APP optional.
Rated Power - 4000W
Peak Power(20ms) - 12000VA
Start Motor - 3HP
Battery Voltage - 48/96VDC
Size(L*W*Hmm) - 491x260x490
Packing Size(L*W*Hmm) - 545x315x550
N.W.(kg) - 36
G.W.(kg) - 39
Installation Method - Tower
Rated Power - 5000W
Peak Power(20ms) - 15000VA
Start Motor - 4HP
Battery Voltage - 48/96VDC
Size(L*W*Hmm) - 491x260x490
Packing Size(L*W*Hmm) - 545x315x550
N.W.(kg) - 36
G.W.(kg) - 39
Installation Method - Tower
Rated Power - 6000W
Peak Power(20ms) - 18000VA
Start Motor - 4HP
Battery Voltage - 48/96VDC
Size(L*W*Hmm) - 491x260x490
Packing Size(L*W*Hmm) - 545x315x550
N.W.(kg) - 36
G.W.(kg) - 39
Installation Method - Tower
Rated Power - 7000W
Peak Power(20ms) - 21000VA
Start Motor - 5HP
Battery Voltage - 48/96/192VDC
Size(L*W*Hmm) - 491x260x490
Packing Size(L*W*Hmm) - 545x315x550
N.W.(kg) - 36
G.W.(kg) - 39
Installation Method - Tower
Input
DC Input Voltage Range - 10.5-15VDC(Single battery voltage)
AC Input Voltage Range - 73 VAC~138 VAC(110VAC) / 83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) /
155VAC~285VAC(230VAC) / 165VAC~295VAC( 240VAC)
AC Input Frequency Range - 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz)
Max AC charging current - 0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power)
AC charging method - Three-stage (constant current, constant voltage, floating charge)
Output
Efficiency(Battery Mode) - ≥85%
Output Voltage(Battery Mode) - 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
Output Frequency(Battery Mode) - 50Hz±0.5 or 60Hz±0.5
Output Wave(Battery Mode) - Pure Sine Wave
Efficiency(AC Mode) - >99%
Output Voltage(AC Mode) - Follow input
Output Frequency(AC Mode) - Tracking Automatically
Output waveform distortion (Battery Mode) - ≤3%(Linear load)
No load loss(Battery Mode) - ≤1% rated power
No load loss(AC Mode) - ≤2% rated power( charger does not work in AC mode)
No load loss (Energy saving Mode) - ≤10W
Battery Type(selectable)
VRLA Battery - Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
Customise battery - Charging and discharging parameters of different types of batteries can be customised according to user requirements (charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection
Battery undervoltage alarm - Factory default: 11V(Single battery voltage)
Battery undervoltage protection - Factory default: 10.5V(Single battery voltage)
Battery overvoltage alarm - Factory default: 15V(Single battery voltage)
Battery overvoltage protection - Factory default: 17V(Single battery voltage)
Battery overvoltage recovery voltage - Factory default: 14.5V(Single battery voltage)
Overload power protection - Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection - Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection - >90°C(Shut down output)
Alarm
A - Normal working condition, buzzer has no alarm sound
B - Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C - When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller (Optional)
Charging Mode - PWM or MPPT
Charging Current - 48V(PWM:10A~120A/MPPT:10A~100A) / 96V(50A/100A(PWM or MPPT))
PV Input Voltage Range - PWM: 60V-88V(48V system); 120V-176V(96V system) / MPPT: 60V-120V(48V system); 120V-240V(96V system)
Max PV Input Voltage(Voc)(At the lowest temperature) - PWM: 100V(48V system); 200V(96V system) / MPPT: 150V(48V system); 300V(96V system)