- New
Allsda Energy All in One Solar Systems
All in One Energy Storage Systems - 3KW, 4KW, 5KW or 6KW Single Phase Hybrid Inverters combined with Lithium Battery Stackable Packs in 5.12KWh, 6.14KWh, and 10.24KWh units. All in one Residential Solar Solutions
FEATURES
Single Phase Inverters combined with low voltage lithium battery units - 5120/6140Wh
6000 Battery cycle life
3-6KW Inverter Power
Multiple Safety Protection - Relay, Fuse. DC Breaker
Remote Monitoring - Self developed APP
WIFI/GPRS/LAN communication optional
INVERTER PARAMETERS
3KW Version
Max DC power - 4500W
Max DC voltage - 500VDC
MPPT voltage range: 100-450VDC
Rated PV Input Voltage - 360V(100-500V)
Full Load DC Voltage Range: 200-425V
PV Input Current 13A+13A 26A+26A
Max PV ISC - 25A+25A
Number of MPP trackers - 2
Number of input string - 1+1
BATTERY INPUT
Battery Type: Li-LON
Battery voltage range: 40-60v
Maximum discharge current - 80/80A
External temperature sensor - Yes
Charging curve - 3 Stages/Equalization
Charge strategy for Li-thium Battery - Self-adaption to BMS
OUTPUT
Rated AC output active power - 3000VA
Max AC apparent power( AC Output) - 3300VA
AC output rated current - 13.1A
Max AC output current - 15A
Max continuous AC passthrough - 35A
Peak power(off grid) - 2 time of rated power, 10s
Power factor adjustment range - 0.8 leading to 0.8 lagging
Power factor - 1
Output frequency and voltage - 50/60Hz; L/N/PE 220/230 VAC
Grid type - Single phase
Total harmonic distortion(THD) - <0.5%In
EFFICIENCY
Maximum conversion efficiency - 97.6%
European efficiency - 96.5%
MPPT efficiency - 99.9%
4KW Version
Max DC power - 6000W
Max DC voltage - 500VDC
MPPT voltage range: 100-450VDC
Rated PV Input Voltage - 360V(100-500V)
Full Load DC Voltage Range: 200-425V
PV Input Current 13A+13A 26A+26A
Max PV ISC - 25A+25A
Number of MPP trackers - 2
Number of input string - 1+1
BATTERY INPUT
Battery Type: Li-LON
Battery voltage range: 40-60v
Maximum discharge current - 100/100A
External temperature sensor - Yes
Charging curve - 3 Stages/Equalization
Charge strategy for Li-thium Battery - Self-adaption to BMS
OUTPUT
Rated AC output active power - 4000VA
Max AC apparent power( AC Output) - 4400VA
AC output rated current - 17.4A
Max AC output current - 20A
Max continuous AC passthrough - 35A
Peak power(off grid) - 2 time of rated power, 10s
Power factor adjustment range - 0.8 leading to 0.8 lagging
Power factor - 1
Output frequency and voltage - 50/60Hz; L/N/PE 220/230 VAC
Grid type - Single phase
Total harmonic distortion(THD) - <0.5%In
EFFICIENCY
Maximum conversion efficiency - 97.6%
European efficiency - 96.5%
MPPT efficiency - 99.9%
5KW Version
Max DC power - 7500W
Max DC voltage - 500VDC
MPPT voltage range: 100-450VDC
Rated PV Input Voltage - 360V(100-500V)
Full Load DC Voltage Range: 200-425V
PV Input Current 13A+13A 26A+26A
Max PV ISC - 25A+25A
Number of MPP trackers - 2
Number of input string - 1+1
BATTERY INPUT
Battery Type: Li-LON
Battery voltage range: 40-60V
Maximum discharge current - 120/120A
External temperature sensor - Yes
Charging curve - 3 Stages/Equalization
Charge strategy for Li-thium Battery - Self-adaption to BMS
OUTPUT
Rated AC output active power - 5000VA
Max AC apparent power( AC Output) - 5500VA
AC output rated current - 21.7A
Max AC output current - 25A
Max continuous AC passthrough - 35A
Peak power(off grid) - 2 time of rated power, 10s
Power factor adjustment range - 0.8 leading to 0.8 lagging
Power factor - 1
Output frequency and voltage - 50/60Hz; L/N/PE 220/230 VAC
Grid type - Single phase
Total harmonic distortion(THD) - <0.5%In
EFFICIENCY
Maximum conversion efficiency - 97.6%
European efficiency - 96.5%
MPPT efficiency - 99.9%
6KW Version
Max DC power - 9000W
Max DC voltage - 500VDC
MPPT voltage range: 100-450VDC
Rated PV Input Voltage - 360V(100-500V)
Full Load DC Voltage Range: 200-425V
PV Input Current 13A+13A 26A+26A
Max PV ISC - 25A+25A
Number of MPP trackers - 2
Number of input string - 1+1
BATTERY INPUT
Battery Type: Li-LON
Battery voltage range: 40-60V
Maximum discharge current - 150/150A
External temperature sensor - Yes
Charging curve - 3 Stages/Equalization
Charge strategy for Li-thium Battery - Self-adaption to BMS
OUTPUT
Rated AC output active power - 6000VA
Max AC apparent power( AC Output) - 6600VA
AC output rated current - 26.1A
Max AC output current - 28.8A
Max continuous AC passthrough - 50A
Peak power(off grid) - 2 time of rated power, 10s
Power factor adjustment range - 0.8 leading to 0.8 lagging
Power factor - 1
Output frequency and voltage - 50/60Hz; L/N/PE 220/230 VAC
Grid type - Single phase
Total harmonic distortion(THD) - <0.5%In
EFFICIENCY
Maximum conversion efficiency - 97.8%
European efficiency - 96.6%
MPPT efficiency - 99.9%
SAFETY AND PROTECTION
Integrated - Anti-islanding protection, PV String Input Reverse Polarity Protection,
Insulation Resistor Detection, Residual Current Monitoring Unit,
Output Overcurrent Protection Output Shorted Protection, Surge Protection
Over voltage category - DC Type Il/AC Type Ill
GENERAL PARAMETERS
Dimension (L*W*H) - 600*205*560mm
Weight - 29kgs
Operating temperature range ºC: -40°C...+60°C, >45 °Cderating
Degree of protection - IP65
Cooling concept - Natural convection
Display - LCD
Installation Style - Wall mounting
Communication - Standard WiFi;GPRS/LAN(optional)
Warranty - Standard 5 years; 7/10 years optional
BMS communication - CAN/RS485
Noise: <30dB
BATTERY PARAMETERS
5.12 kWh version
Total energy - 5.1 kWh
Usable energy (CC) - 4.6 kWh
Rated discharge/charge power - 3.0 kW
Peak power (discharge only) - 6 kW for 3 s
Constant current (discharge only) – 80 A.
Voltage -48~56Vd.c
Rated voltage - 51.2 Vd.c
Rated current - 60A
Max. Charging voltage - 57.6 Vd.c
Weight - 45kg