Xindun Hybrid Solar Inverters
HDSX 3-Phase Low Frequency Inverters: 3.2KW-12KW - Three phase off grid hybrid solar inverters which can be used in single-phase and three-phase ac load: 3.2KW-12KW, 48V. Three phase Inverter Chargers, Pure sine wave &AVR output, Low Frequency 100% imbalance loading design, 100% Full power capacity, High performance & Stability
Pure sine wave output.
Low DC voltage, saving system cost.
3 phase solar inverter with built-in PWM or MPPT charge controller.
AC charge current 0-45A adjustable.
Wide LCD screen, clearly and precisely shows icon data.
100% imbalance loading design, 3 times peak power.
Setting different working modes based on variable usage requirements.
DC first/AC first optional.
Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional)
3.2KW Version
Rated Power - 3.2KW
Peak Power(20ms) - 9.6VA
Start Motor - 3HP
Battery Voltage - 48/96/192VDC
4.8KW Version
Rated Power - 4.8KW
Peak Power(20ms) - 14.4VA
Start Motor - 4HP
Battery Voltage - 48/96/192VDC
5.6KW Version
Rated Power - 5.6KW
Peak Power(20ms) - 16.8VA
Start Motor - 4HP
Battery Voltage - 48/96/192VDC
6.4KW Version
Rated Power - 6.4KW
Peak Power(20ms) - 19.2VA
Start Motor - 4HP
Battery Voltage - 48/96/192VDC
PRODUCT PARAMETERS
INPUT
DC Input Voltage Range - 10.5-15VDC(Single battery voltage)
AC Input Voltage Range - 380Vac/400Vac±10%(customised 190 Vac/200Vac)
AC Input Frequency Range- 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current - 0A~45A(Depending on the model
AC charging method - Three-stage (constant current, constant voltage, floating charge)
Phase - 3/N/PE
OUTPUT
Efficiency(Battery Mode) - ≥85%
Output Voltage(Battery Mode) - 380Vac/400Vac±10%(customised 190 Vac/200Vac)
Output Frequency(Battery Mode) - 50/60Hz±1%
Output Wave(Battery Mode) - Pure Sine Wave
Efficiency(AC Mode) - >99%
Output Voltage(AC Mode) - 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Output Frequency(AC Mode) - Tracking Automatically
Output waveform distortion (Battery Mode) - ≤3%(Linear load)
No load loss(Battery Mode) - ≤0.8% rated power
No load loss(AC Mode) - ≤2% rated power( charger does not work in AC mode)
No load loss(Energy saving Mode) - ≤10W
BATTERY TYPE
VRLA Battery - Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customise battery - Charging and discharging parameters of different types of batteries can be customised according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Battery undervoltage alarm - Factory default: 11V(12V system; 24V system x2; 48V system x4)
Battery undervoltage protection - Factory default: 10.5V(12V system; 24V system x2; 48V system x4)
Battery overvoltage alarm - Factory default: 15V(12V system; 24V system x2; 48V system x4)
Battery overvoltage protection - Factory default: 17V(12V system; 24V system x2; 48V system x4)
Battery overvoltage recovery voltage - Factory default: 14.5V(12V system; 24V system x2; 48V system x4)
Overload power protection - Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection - Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection - >90°C(Shut down output)
ALARM
A- Normal working condition, buzzer has no alarm sound
B - Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C - When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
INSIDE SOLAR CONTROLLER (OPTIONAL)
Charging Mode - PWM or MPPT
Charging Current - PWM: 10A-60A(48V System); 50A/100A(96V System); 50A(192V System) 3.23.2 MPPT: 10A-100A(48V System); 50A/100A(96V System)
PV Input Voltage Range - PWM: 60V-88V(48V System); 120V-176V(96V System); 240V-352V(192V System) MPPT: 60V-120V(48V System); 120V-240V(96V System); 240V-360V(192V System)
Max PV Input Voltage(Voc)(At the lowest temperature) - PWM: 100V(48V System); 200V(96V System); 400V(192V System) MPPT: 150V(48 System); 300V(96V System); 450V(192V System)
PV Array Maximum Power - 48V System: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A); 96V System: (PWM: 5.6KW(50A)/11.2KW(100A)) / (MPPT: 5.6KW(50A)/5.6KW*2(100A)); 192V System: 11.2KW(50A)