Zonergy Apollo On Grid Inverters
Zonergy Apollo Three Phase On Grid Inverters - available in various versions: 8KW, 10KW, 12kW, 15KW, 17KW, 20KW, 25KW, 30KW
-
The DC capacitance ratio can reach as high as 1.5 times, which is perfectly suitable for high current and double-sided solar panels.
-
DC arcing detection function can be selected to eliminate potential fire hazards.
-
The adaptive control algorithm adopted ensures the product fit for an unstable grid.
-
Flexible monitoring modes support RS485, Wi-Fi and GPRS.
-
The product has IP66 degrees of protection and C5 anti-corrosion.
-
The product supports output of 1.1 times overload. This effectively increases power generation.
</
Technical parameters: |
Apollo 8000-T1
|
Apollo 10K-T1
|
Apollo 12K-T1
|
Apollo 15K-T1
|
Apollo 17K-T1
|
Apollo 20K-T1
|
Apollo 25K-T1
|
Apollo 30K-T1
|
Input parameters (DC) |
||||||||
Maximum panel input power recommended (kW) |
12 |
15 |
18 |
22.5 |
25.5 |
30 |
32.5 |
39 |
Maximum DC input voltage (V) |
1100 |
|||||||
Maximum input current of each MPPT (A) |
16 |
20 |
26 |
32 |
||||
Short circuit current of each MPPT (A) |
25 |
25 |
39 |
50 |
||||
Max.Power of each MPPT (kW) |
9.6 |
12 |
15.6 |
19.5 |
||||
No. of MPPT / strings |
2/1 |
2/2 |
2/2 |
2/2+3 |
||||
Start-up voltage (V) |
180 |
|||||||
MPPT Voltage range (V) |
160V~1000 |
|||||||
Full-load MPPT Voltage range (V) |
550~850 |
|||||||
Rated input voltage (V) |
600 |
|||||||
|
Output parameters (AC) |
|||||||
Rated output power (kW) |
8.8kW@40℃ 8kW@45℃ |
11kW@40℃ 10kW@45℃ |
13.2kW@40℃ 12kW@45℃ |
16.5kW@40℃ 15kW@45℃ |
18.7kW@40℃ 17kW@45℃ |
22kW@40℃ 20kW@45℃ |
27.5kW@40℃ 25kW@45℃ |
33kW@40℃ 30kW@45℃ |
Maximum apparent power (kVA) |
8.8 |
11 |
13.2 |
16.5 |
18.7 |
22 |
27.5 |
33 |
Max.output power (kW) |
8.8 |
11 |
13.2 |
16.5 |
18.7 |
22 |
27.5 |
33 |
Output connection type |
3W+PE or 3W+N+PE |
|||||||
Rated voltage/Voltage range (V) |
380/320~480 |
|||||||
Rated grid frequency |
45~55Hz / 55~ 65Hz (According to local grid standards) |
|||||||
Rated output current (A) |
12.2 |
15.2 |
18.2 |
22.8 |
25.8 |
30.4 |
38.0 |
45.6 |
Maximum output current (A) |
13.4 |
16.7 |
20.1 |
25.1 |
28.4 |
33.4 |
41.8 |
50.1 |
Power Factor (settable) |
> 0.99 @ full power (adjustable range: 0.8 leading ~ 0.8 lagging) |
|||||||
Total Harmonic Distortion THDi (full load) |
<3% (full load) |
|||||||
MPPT efficiency |
Efficiency 99.9% |
|||||||
Maximum efficiency |
98.4% |
98.5% |
98.6% |
98.6% |
||||
Euro. efficiency |
97.8% |
98.0% |
98.1% |
98.2% |
||||
China efficiency |
97.5% |
97.8% |
98.0% |
98.0% |
||||
DC switch with Shunt release |
Protection function Available |
|||||||
Output short circuit protection |
Available |
|||||||
Power grid fault monitoring |
Available |
|||||||
DC reverse connection protection |
Available |
|||||||
String monitoring |
Available |
|||||||
DC lightning protection |
type II |
|||||||
AC lightning protection |
type II |
|||||||
DC insulation impedance detection |
Available |
|||||||
AC leakage current detection |
Available |
|||||||
Over-temperature protection |
Available |
|||||||
DC component monitoring |
Available |
|||||||
DC fuse |
/ |
|||||||
Islanding detection |
Available |
|||||||
Smart IV diagnosis |
Available |
|||||||
Arc fault detection |
Optional |
|||||||
Bus voltage monitoring |
Available |
|||||||
PID repair and protection |
Optional |
|||||||
Low Voltage Ride Through |
Available |
|||||||
Arc fault detection |
Option |
|||||||
Remote upgrade and setup |
Available |
|||||||
anti-counterflow meter |
Available |
|||||||
Fault recorded |
<p style="margin-top:0px;margin-bottom:0px;font-family:Arial, 'Helvetica Neue', Helvetica, sans-serif
You might also like
Comments (0)
No customer reviews for the moment.
|