Zonergy Apollo Three Phase On Grid Inverters - available in various versions: 8KW, 10KW, 12kW, 15KW, 17KW, 20KW, 25KW, 30KW
The DC capacitance ratio can reach as high as 1.5 times, which is perfectly suitable for high current and double-sided solar panels.
DC arcing detection function can be selected to eliminate potential fire hazards.
The adaptive control algorithm adopted ensures the product fit for an unstable grid.
Flexible monitoring modes support RS485, Wi-Fi and GPRS.
The product has IP66 degrees of protection and C5 anti-corrosion.
The product supports output of 1.1 times overload. This effectively increases power generation.
</
Technical parameters: |
Apollo 8000-T1
|
Apollo 10K-T1
|
Apollo 12K-T1
|
Apollo 15K-T1
|
Apollo 17K-T1
|
Apollo 20K-T1
|
Apollo 25K-T1
|
Apollo 30K-T1
|
Input parameters (DC) |
||||||||
Maximum panel input power recommended (kW) |
12 |
15 |
18 |
22.5 |
25.5 |
30 |
32.5 |
39 |
Maximum DC input voltage (V) |
1100 |
|||||||
Maximum input current of each MPPT (A) |
16 |
20 |
26 |
32 |
||||
Short circuit current of each MPPT (A) |
25 |
25 |
39 |
50 |
||||
Max.Power of each MPPT (kW) |
9.6 |
12 |
15.6 |
19.5 |
||||
No. of MPPT / strings |
2/1 |
2/2 |
2/2 |
2/2+3 |
||||
Start-up voltage (V) |
180 |
|||||||
MPPT Voltage range (V) |
160V~1000 |
|||||||
Full-load MPPT Voltage range (V) |
550~850 |
|||||||
Rated input voltage (V) |
600 |
|||||||
|
Output parameters (AC) |
|||||||
Rated output power (kW) |
8.8kW@40℃ 8kW@45℃ |
11kW@40℃ 10kW@45℃ |
13.2kW@40℃ 12kW@45℃ |
16.5kW@40℃ 15kW@45℃ |
18.7kW@40℃ 17kW@45℃ |
22kW@40℃ 20kW@45℃ |
27.5kW@40℃ 25kW@45℃ |
33kW@40℃ 30kW@45℃ |
Maximum apparent power (kVA) |
8.8 |
11 |
13.2 |
16.5 |
18.7 |
22 |
27.5 |
33 |
Max.output power (kW) |
8.8 |
11 |
13.2 |
16.5 |
18.7 |
22 |
27.5 |
33 |
Output connection type |
3W+PE or 3W+N+PE |
|||||||
Rated voltage/Voltage range (V) |
380/320~480 |
|||||||
Rated grid frequency |
45~55Hz / 55~ 65Hz (According to local grid standards) |
|||||||
Rated output current (A) |
12.2 |
15.2 |
18.2 |
22.8 |
25.8 |
30.4 |
38.0 |
45.6 |
Maximum output current (A) |
13.4 |
16.7 |
20.1 |
25.1 |
28.4 |
33.4 |
41.8 |
50.1 |
Power Factor (settable) |
> 0.99 @ full power (adjustable range: 0.8 leading ~ 0.8 lagging) |
|||||||
Total Harmonic Distortion THDi (full load) |
<3% (full load) |
|||||||
MPPT efficiency |
Efficiency 99.9% |
|||||||
Maximum efficiency |
98.4% |
98.5% |
98.6% |
98.6% |
||||
Euro. efficiency |
97.8% |
98.0% |
98.1% |
98.2% |
||||
China efficiency |
97.5% |
97.8% |
98.0% |
98.0% |
||||
DC switch with Shunt release |
Protection function Available |
|||||||
Output short circuit protection |
Available |
|||||||
Power grid fault monitoring |
Available |
|||||||
DC reverse connection protection |
Available |
|||||||
String monitoring |
Available |
|||||||
DC lightning protection |
type II |
|||||||
AC lightning protection |
type II |
|||||||
DC insulation impedance detection |
Available |
|||||||
AC leakage current detection |
Available |
|||||||
Over-temperature protection |
Available |
|||||||
DC component monitoring |
Available |
|||||||
DC fuse |
/ |
|||||||
Islanding detection |
Available |
|||||||
Smart IV diagnosis |
Available |
|||||||
Arc fault detection |
Optional |
|||||||
Bus voltage monitoring |
Available |
|||||||
PID repair and protection |
Optional |
|||||||
Low Voltage Ride Through |
Available |
|||||||
Arc fault detection |
Option |
|||||||
Remote upgrade and setup |
Available |
|||||||
anti-counterflow meter |
Available |
|||||||
Fault recorded |
<p style="margin-top:0px;margin-bottom:0px;font-family:Arial, 'Helvetica Neue', Helvetica, sans-serif
You might also like
Comments (0)
No customer reviews for the moment.
|