Xindun Solar Power Inverters
Xindun LF Solar Inverters - in various versions. Low Frequency PV Inverters: 1KW-6KW 12V/24V/48V. Inverter 1000W-6000W, DC 12V/24V/48V to Single Phase AC110V/120V/220V/230V/240V, or to Split Phase AC 110V&220V, AC120V&240V
FEATURES
Low frequency solar inverter full sine wave output, good waveform, less distortion, better quality than the power grid, suitable for various inductive loads.
Solar charger, AC charger, generator charger, battery charger all in one.
Remote communication:home inverter can be connected with a computer or app by RS485,WIFI,GPRS; communicate with a lithium battery by RS485,you can choose according to your needs.
Optional built-in MPPT solar charge controller,maximum power point tracking, efficiency up to 99%.
Multiple Battery Options:the home office inverter compatible with agm batteries, gel batteries, opzv, opzs, lifepo4, lithium ion batteries, etc.
1.5KW-6KW split phase office inverter dual output 120v&240v, or 110v&220v
Complete Protections: Overload/Over temperature/Short circuit protection. Smart battery charger design for optimised battery performance. Intelligent variable speed fans efficiently dissipate heat and extend system life.
Rated Power - 1000W Version
Phase Type - Single phase L-N ; Split phase can be customised L1-L2,L1-N,L2-N
Battery
Standard Battery Voltage - 12/24/48VDC
Battery Type - Lead-acid / Gel Battery / Lithium Batteries / Custom battery
AC Input
Rated Input Voltage - 110VAC/120VAC/220VAC /230VAC/ 240VAC
AC Input Voltage Range - 85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC)/ 170VAC~275VAC(220VAC)180VAC~285VAC(230VAC)/ 190VAC~295VAC(240VA)
AC Input Frequency Range - 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz)
AC Output
Output Wave / Conversion Efficiency - Pure Sine Wave/>85%
AC Output Voltage / Frequency Range(INV mode) - 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Built-in MPPT Solar Charge Controller - Optional
Rated Current - 30A
PV Array Max Power - 12V(420W)/24V(840W)/48V(1680W)
Max PV Input Voltage(Voc)(At The Lowest Temperature) - 12V/24V system:120VDC
MPPT Tracking Voltage Range - 12V System(15V-80V)/24V System(30V-100V)/48V System(60V-140V)
Other
Protection - Battery undervoltage protection/Battery overvoltage protection/Overload power protection/Inverter output short circuit protection/Temperature protection
Protection Degree - IP20
Display - LCD
Cooling Method - Cooling Fan in Intelligent Control
Communication Interfaces - RS485/RS232,APP(WIFI monitoring or GPRS monitoring)Optional
Working Mode(settable) - Battery priority / Mains priority
Operating Temperature: -15℃~40℃
Relative Humidity - 0%~95% , No Condensation
Dimensions and Weight
Product Size(L*W*Hmm) - 500*300*140
Packing Size(L*W*Hmm) - 550*365*223
N.W.(kg) - 12kg
G.W.(kg) - 13.5kg
Rated Power - 1500W Version
Phase Type - Single phase L-N ; Split phase can be customised L1-L2,L1-N,L2-N
Battery
Standard Battery Voltage - 12/24/48VDC
Battery Type - Lead-acid / Gel Battery / Lithium Batteries / Custom battery
AC Input
Rated Input Voltage - 110VAC/120VAC/220VAC /230VAC/ 240VAC
AC Input Voltage Range - 85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC)/ 170VAC~275VAC(220VAC)180VAC~285VAC(230VAC)/ 190VAC~295VAC(240VA)
AC Input Frequency Range - 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz)
AC Output
Output Wave / Conversion Efficiency - Pure Sine Wave/>85%
AC Output Voltage / Frequency Range(INV mode) - 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Built-in MPPT Solar Charge Controller - Optional
Rated Current - 30A
PV Array Max Power - 12V(420W)/24V(840W)/48V(1680W)
Max PV Input Voltage(Voc)(At The Lowest Temperature) - 12V/24V system:120VDC
MPPT Tracking Voltage Range - 12V System(15V-80V)/24V System(30V-100V)/48V System(60V-140V)
Other
Protection - Battery undervoltage protection/Battery overvoltage protection/Overload power protection/Inverter output short circuit protection/Temperature protection
Protection Degree - IP20
Display - LCD
Cooling Method - Cooling Fan in Intelligent Control
Communication Interfaces - RS485/RS232,APP(WIFI monitoring or GPRS monitoring)Optional
Working Mode(settable) - Battery priority / Mains priority
Operating Temperature: -15℃~40℃
Relative Humidity - 0%~95% , No Condensation
Dimensions and Weight
Product Size(L*W*Hmm) - 500*300*140
Packing Size(L*W*Hmm) - 550*365*223
N.W.(kg) - 13.5kg
G.W.(kg) - 15kg
Rated Power - 2000W Version
Phase Type - Single phase L-N ; Split phase can be customised L1-L2,L1-N,L2-N
Battery
Standard Battery Voltage - 12/24/48VDC
Battery Type - Lead-acid / Gel Battery / Lithium Batteries / Custom battery
AC Input
Rated Input Voltage - 110VAC/120VAC/220VAC /230VAC/ 240VAC
AC Input Voltage Range - 85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC)/ 170VAC~275VAC(220VAC)180VAC~285VAC(230VAC)/ 190VAC~295VAC(240VA)
AC Input Frequency Range - 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz)
AC Output
Output Wave / Conversion Efficiency - Pure Sine Wave/>85%
AC Output Voltage / Frequency Range(INV mode) - 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Built-in MPPT Solar Charge Controller - Optional
Rated Current - 60A
PV Array Max Power - 12V(840W)/24V(1680W)/48V(3360W)
Max PV Input Voltage(Voc)(At The Lowest Temperature) - 12V/24V system:120VDC
MPPT Tracking Voltage Range - 12V System(15V-80V)/24V System(30V-100V)/48V System(60V-140V)
Other
Protection - Battery undervoltage protection/Battery overvoltage protection/Overload power protection/Inverter output short circuit protection/Temperature protection
Protection Degree - IP20
Display - LCD
Cooling Method - Cooling Fan in Intelligent Control
Communication Interfaces - RS485/RS232,APP(WIFI monitoring or GPRS monitoring)Optional
Working Mode(settable) - Battery priority / Mains priority
Operating Temperature: -15℃~40℃
Relative Humidity - 0%~95% , No Condensation
Dimensions and Weight
Product Size(L*W*Hmm) - 500*300*140
Packing Size(L*W*Hmm) - 550*365*223
N.W.(kg) - 18kg
G.W.(kg) - 19.5kg
Rated Power - 3000W Version
Phase Type - Single phase L-N ; Split phase can be customised L1-L2,L1-N,L2-N
Battery
Standard Battery Voltage - 24/48VDC
Battery Type - Lead-acid / Gel Battery / Lithium Batteries / Custom battery
AC Input
Rated Input Voltage - 110VAC/120VAC/220VAC /230VAC/ 240VAC
AC Input Voltage Range - 85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC)/ 170VAC~275VAC(220VAC)180VAC~285VAC(230VAC)/ 190VAC~295VAC(240VA)
AC Input Frequency Range - 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz)
AC Output
Output Wave / Conversion Efficiency - Pure Sine Wave/>85%
AC Output Voltage / Frequency Range(INV mode) - 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Built-in MPPT Solar Charge Controller - Optional
Rated Current - 60A
PV Array Max Power - 12V(840W)/24V(1680W)/48V(3360W)
Max PV Input Voltage(Voc)(At The Lowest Temperature) - 12V/24V system:120VDC
MPPT Tracking Voltage Range - 12V System(15V-80V)/24V System(30V-100V)/48V System(60V-140V)
Other
Protection - Battery undervoltage protection/Battery overvoltage protection/Overload power protection/Inverter output short circuit protection/Temperature protection
Protection Degree - IP20
Display - LCD
Cooling Method - Cooling Fan in Intelligent Control
Communication Interfaces - RS485/RS232,APP(WIFI monitoring or GPRS monitoring)Optional
Working Mode(settable) - Battery priority / Mains priority
Operating Temperature: -15℃~40℃
Relative Humidity - 0%~95% , No Condensation
Dimensions and Weight
Product Size(L*W*Hmm) - 530*335*150
Packing Size(L*W*Hmm) - 610*400*233
N.W.(kg) - 20kg
G.W.(kg) - 21.5kg
Rated Power - 4000W Version
Phase Type - Single phase L-N ; Split phase can be customised L1-L2,L1-N,L2-N
Battery
Standard Battery Voltage - 24/48VDC
Battery Type - Lead-acid / Gel Battery / Lithium Batteries / Custom battery
AC Input
Rated Input Voltage - 110VAC/120VAC/220VAC /230VAC/ 240VAC
AC Input Voltage Range - 85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC)/ 170VAC~275VAC(220VAC)180VAC~285VAC(230VAC)/ 190VAC~295VAC(240VA)
AC Input Frequency Range - 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz)
AC Output
Output Wave / Conversion Efficiency - Pure Sine Wave/>85%
AC Output Voltage / Frequency Range(INV mode) - 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Built-in MPPT Solar Charge Controller - Optional
Rated Current - 60A
PV Array Max Power - 12V(840W)/24V(1680W)/48V(3360W)
Max PV Input Voltage(Voc)(At The Lowest Temperature) - 12V/24V system:120VDC
MPPT Tracking Voltage Range - 12V System(15V-80V)/24V System(30V-100V)/48V System(60V-140V)
Other
Protection - Battery undervoltage protection/Battery overvoltage protection/Overload power protection/Inverter output short circuit protection/Temperature protection
Protection Degree - IP20
Display - LCD
Cooling Method - Cooling Fan in Intelligent Control
Communication Interfaces - RS485/RS232,APP(WIFI monitoring or GPRS monitoring)Optional
Working Mode(settable) - Battery priority / Mains priority
Operating Temperature: -15℃~40℃
Relative Humidity - 0%~95% , No Condensation
Dimensions and Weight
Product Size(L*W*Hmm) - 530*335*150
Packing Size(L*W*Hmm) - 610*400*233
N.W.(kg) - 22kg
G.W.(kg) - 24kg
Rated Power - 5000W Version
Phase Type - Single phase L-N ; Split phase can be customised L1-L2,L1-N,L2-N
Battery
Standard Battery Voltage - 48VDC
Battery Type - Lead-acid / Gel Battery / Lithium Batteries / Custom battery
AC Input
Rated Input Voltage - 110VAC/120VAC/220VAC /230VAC/ 240VAC
AC Input Voltage Range - 85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC)/ 170VAC~275VAC(220VAC)180VAC~285VAC(230VAC)/ 190VAC~295VAC(240VA)
AC Input Frequency Range - 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz)
AC Output
Output Wave / Conversion Efficiency - Pure Sine Wave/>85%
AC Output Voltage / Frequency Range(INV mode) - 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Built-in MPPT Solar Charge Controller - Optional