E-Able MPS Hybrid Solar Power Inverters
search
  • E-Able MPS Hybrid Solar Power Inverters
  • E-Able MPS Hybrid Solar Power Inverters

E-Able MPS Hybrid Solar Power Inverters

£260.00
No tax 7-10 days

E-Able MPS-VIII Eco Series Hybrid On/Off Grid Hybrid Solar Power Inverters: available in three versions - 3.6KW/4.2KW/6.2KW

Specifications: 3.6KW Hybrid On/Off Inverter
Quantity

FEATURES

Pure sine wave solar inverter (on/off-grid)

WIFI & GPRS available for lOS and Android

Inverter running without a battery

One-key restored to factory settings

Built-in lithium battery automatic activation

Built-in 120A (for 3.6 KW/4.2 KW) 120A (for 6.2 KW)

MPPT: max 6200W(for 3.6KW)max 6200W(for 4.2KW) max 6500W(for 6.2KW) solar charge

High PV input voltage range(90~450VDC)

Built-in anti-dust kit for harsh environment

Smart battery charge design to optimise battery life

Dual output

DESCRIPTION

3600W Version 1-Phase

Maximum PV Input Power - 6200W

Rated Output Power - 3600W/3600VA

Maximum Solar Charging Current - 120A

GRID-TIE OPERATION

PV Input(DC)

Nominal DC Voltage/Maximum DC Voltage - 360VDC/500VDC

Start-up Voltage/Initial Feeding Voltage - 60VDC/90VDC

Maximum DC Voltage - 60VDC-450VDC

Number of MPPT trackers/Maximum Input Current - 1/23A

GRID OUTPUT (AC)

Nominal Output Voltage - 1200/230/240VAC

Output Voltage Range - 195.5-253 VAC

Nominal Output Current - 15.7A

Power Factor: >0.99

Feed-in Grid Frequency Range - 49-51+-1Hz

EFFICIENCY

Maximum Conversion Efficiency(Solar/AC) - 98%

TWO LOAD OUTPUT POWER (V2.0)

Full Load - 3600W

Maximum Main Load - 3600W

Maximum Second Load (Battery Mode) - 1200W

Main Load Cut Off Voltage - 22VDC

Main Load Return Voltage - 26VDC

OFF GRID OPERATION

AC INPUT

AC Start-up Voltage/Auto Restart Voltage - 120-140VAC/180VAC

Acceptable Input Voltage Range - 90-280VAC or 170-280VAC

Maximum AC Input Current - 40A

Nominal Operating Frequency - 50/60Hz

Surge Power - 7200W

BATTERY MODE OUTPUT(AC)

Nominal Output Voltage - 220/230/240VAC

Output Waveform - Pure sinewave

Efficiency(DC to AC) -94%

BATTERY & CHARGER

Nominal DC Voltage - 24VDC

Maximum Solar Charging Current (Solar to AC) - 120A

Maximum AC Charging Current - 100A

INTERFACE

Communication Port - RS232/GPRS/WIFI

ENVIRONMENT

Operating Temperature: -10C to 55C



4200W Version 1-Phase

Maximum PV Input Power - 6200W

Rated Output Power - 4200W

Maximum Solar Charging Current - 120A

GRID-TIE OPERATION

PV Input(DC)

Nominal DC Voltage/Maximum DC Voltage - 360VDC/500VDC

Start-up Voltage/Initial Feeding Voltage - 60VDC/90VDC

Maximum DC Voltage - 60VDC-450VDC

Number of MPPT trackers/Maximum Input Current - 1/23A

GRID OUTPUT (AC)

Nominal Output Voltage - 1200/230/240VAC

Output Voltage Range - 195.5-253 VAC

Nominal Output Current - 18.2A

Power Factor: >0.99

Feed-in Grid Frequency Range - 49-51+-1Hz

EFFICIENCY

Maximum Conversion Efficiency(Solar/AC) - 98%

TWO LOAD OUTPUT POWER (V2.0)

Full Load - 4200W

Maximum Main Load - 4200W

Maximum Second Load (Battery Mode) - 1400W

Main Load Cut Off Voltage - 22VDC

Main Load Return Voltage - 26VDC

OFF GRID OPERATION

AC INPUT

AC Start-up Voltage/Auto Restart Voltage - 120-140VAC/180VAC

Acceptable Input Voltage Range - 90-280VAC or 170-280VAC

Maximum AC Input Current - 40A

Nominal Operating Frequency - 50/60Hz

Surge Power - 8400W

BATTERY MODE OUTPUT(AC)

Nominal Output Voltage - 220/230/240VAC

Output Waveform - Pure sinewave

Efficiency(DC to AC) -94%

BATTERY & CHARGER

Nominal DC Voltage - 24VDC

Maximum Solar Charging Current (Solar to AC) - 120A

Maximum AC Charging Current - 100A

INTERFACE

Communication Port - RS232/GPRS/WIFI

ENVIRONMENT

Operating Temperature: -10C to 55C





6200W Version 1-Phase

Maximum PV Input Power - 6500W

Rated Output Power - 6200W/6200VA

Maximum Solar Charging Current - 120A

GRID-TIE OPERATION

PV Input(DC)

Nominal DC Voltage/Maximum DC Voltage - 360VDC/500VDC

Start-up Voltage/Initial Feeding Voltage - 60VDC/90VDC

Maximum DC Voltage - 60VDC-450VDC

Number of MPPT trackers/Maximum Input Current - 1/23A

GRID OUTPUT (AC)

Nominal Output Voltage - 1200/230/240VAC

Output Voltage Range - 195.5-253 VAC

Nominal Output Current - 27.0A

Power Factor: >0.99

Feed-in Grid Frequency Range - 49-51+-1Hz

EFFICIENCY

Maximum Conversion Efficiency(Solar/AC) - 98%

TWO LOAD OUTPUT POWER (V2.0)

Full Load - 5000W

Maximum Main Load - 5000W-10000W

Maximum Second Load (Battery Mode) - 1666W-3333W

Main Load Cut Off Voltage - 44VDC

Main Load Return Voltage - 52VDC

OFF GRID OPERATION

AC INPUT

AC Start-up Voltage/Auto Restart Voltage - 120-140VAC/180VAC

Acceptable Input Voltage Range - 90-280VAC or 170-280VAC

Maximum AC Input Current - 50A

Nominal Operating Frequency - 50/60Hz

Surge Power - 10000W

BATTERY MODE OUTPUT(AC)

Nominal Output Voltage - 220/230/240VAC

Output Waveform - Pure sinewave

Efficiency(DC to AC) -94%

BATTERY & CHARGER

Nominal DC Voltage - 48VDC

Maximum Solar Charging Current (Solar to AC) - 120A

Maximum AC Charging Current - 100A

INTERFACE

Communication Port - RS232/GPRS/WIFI

ENVIRONMENT

Operating Temperature: -10C to 55C

 

E-Able MPS Hybrid Solar Power Inverters
100 Items

You might also like

Comments (0)
No customer reviews for the moment.