• New
TTnergy HAF Solar Inverters
search
  • TTnergy HAF Solar Inverters
  • TTnergy HAF Solar Inverters

TTnergy HAF Solar Inverters

£270.00
No tax 3-4 weeks

TTnergy HAF Solar Storage Inverters - available in 3KW/5KW versions

Specifications: 3KW Hybrid Inverter
Quantity

FEATURES

Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sine wave.

Two output modes: mains bypass and inverter output; uninterrupted power supply.

Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Main & Solar hybrid charging.

Advanced MPPT technology with an efficiency of 99.9%.

With the charging requirement (voltage, current, mode) settings, and suitable for various types of energy storage batteries.

ON/OFF rocker switch for AC output control.
Power saving mode available to reduce no-load loss.
Intelligent variable speed fan to efficiently dissipate heat and extend system life.

Lithium battery activation design, allowing access of lead-acid battery and lithium battery.

360 °all-round protection with a number of protection functions. Such as overload, short circuit and overcurrent.

Supply of a variety of user-friendly communication modules, such as Rs485(GPRS,WiFi), CAN, USB etc., and suitable for computer, mobile phones, internet monitoring as well as remote operations

 

3KW Version

AC MODE

Rated input voltage - 220/230VAC

Input voltage range - (1(170Vac~280Vac)+2%; (90Vac-280Vac)+2%

Frequency - 50Hz/60Hz(auto-sensing)

Frequency Range - 47+0.3Hz~55+0.3Hz(50Hz)/57+0.3Hz~65+0.3Hz(60Hz);

Overload/short circuit protection - Breaker

Efficiency: >95%

Conversion time (bypass and inverter) - 10ms (Typical value)

AC reverse protection - Available

Maximum bypass overload current - 40A

Inverter mode

Output voltage waveform - Pure sine wave

Rated output power(VA) - 3000(2600/2700/3000)

Rated output power(W) - 3000(2600/2700/3000)

Power factor - 1

Rated output voltage (Vac) - 230Vac(200/208/220/240Vac settable)

Output voltage error - ±5%

Output frequency range (Hz) - 50Hz+0.3HZ/60Hz±0.3HZ

Efficiency - >90%

Overload protection - (102%<load<125%) +10%: reporting error and turn off the output after 5 minutes;(125%<load<150%) +10%: reporting error and turn off the output after 10 seconds;Load>150% +10%: reporting error and turn off the output after 5 seconds

Peak Power - 6000VA

Loaded motor capacity - 2HP

Output short-circuit protection - Breaker

Specification of bypass breaker - 40A

Rated battery input voltage - 48V (minimum start voltage 44V)

Battery voltage range - 40.0vdc~60Vdc + 0.6Vdc (undervoltage alarm/turn off voltage/overvoltage alarm/overvoltage restoration, settable lCD screen)

Power saving mode - Load≤50W

AC charge

Battery type - Lead acid or lithium battery

Maximum charge current - 60A

Charge current error - ±5 Adc

Charge voltage range - 40Vdc~60Vdc

Short-circuit protection - Breaker and blown fuse

Breaker specification - 40A

Overcharge protection - Turn off charge after 1min alarm

Solar charge

Maximum PV open circuit voltage - 500Vdc

PV operation voltage range: 120-500Vdc

MPPT voltage range: 120-500Vdc

Battery voltage range: 40-60Vdc

Maximum output power - 4200W

Charge current range of solar energy (settable): 0-60A

11Charge short-circuit protection - Blown fuse

Wiring protection - Inverse wiring protection

Weight - 10.9kg

 