- New
TTnergy HAF Solar Inverters
TTnergy HAF Solar Storage Inverters - available in 3KW/5KW versions
FEATURES
Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sine wave.
Two output modes: mains bypass and inverter output; uninterrupted power supply.
Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Main & Solar hybrid charging.
Advanced MPPT technology with an efficiency of 99.9%.
With the charging requirement (voltage, current, mode) settings, and suitable for various types of energy storage batteries.
ON/OFF rocker switch for AC output control.
Power saving mode available to reduce no-load loss.
Intelligent variable speed fan to efficiently dissipate heat and extend system life.
Lithium battery activation design, allowing access of lead-acid battery and lithium battery.
360 °all-round protection with a number of protection functions. Such as overload, short circuit and overcurrent.
Supply of a variety of user-friendly communication modules, such as Rs485(GPRS,WiFi), CAN, USB etc., and suitable for computer, mobile phones, internet monitoring as well as remote operations
3KW Version
AC MODE
Rated input voltage - 220/230VAC
Input voltage range - (1(170Vac~280Vac)+2%; (90Vac-280Vac)+2%
Frequency - 50Hz/60Hz(auto-sensing)
Frequency Range - 47+0.3Hz~55+0.3Hz(50Hz)/57+0.3Hz~65+0.3Hz(60Hz);
Overload/short circuit protection - Breaker
Efficiency: >95%
Conversion time (bypass and inverter) - 10ms (Typical value)
AC reverse protection - Available
Maximum bypass overload current - 40A
Inverter mode
Output voltage waveform - Pure sine wave
Rated output power(VA) - 3000(2600/2700/3000)
Rated output power(W) - 3000(2600/2700/3000)
Power factor - 1
Rated output voltage (Vac) - 230Vac(200/208/220/240Vac settable)
Output voltage error - ±5%
Output frequency range (Hz) - 50Hz+0.3HZ/60Hz±0.3HZ
Efficiency - >90%
Overload protection - (102%<load<125%) +10%: reporting error and turn off the output after 5 minutes;(125%<load<150%) +10%: reporting error and turn off the output after 10 seconds;Load>150% +10%: reporting error and turn off the output after 5 seconds
Peak Power - 6000VA
Loaded motor capacity - 2HP
Output short-circuit protection - Breaker
Specification of bypass breaker - 40A
Rated battery input voltage - 48V (minimum start voltage 44V)
Battery voltage range - 40.0vdc~60Vdc + 0.6Vdc (undervoltage alarm/turn off voltage/overvoltage alarm/overvoltage restoration, settable lCD screen)
Power saving mode - Load≤50W
AC charge
Battery type - Lead acid or lithium battery
Maximum charge current - 60A
Charge current error - ±5 Adc
Charge voltage range - 40Vdc~60Vdc
Short-circuit protection - Breaker and blown fuse
Breaker specification - 40A
Overcharge protection - Turn off charge after 1min alarm
Solar charge
Maximum PV open circuit voltage - 500Vdc
PV operation voltage range: 120-500Vdc
MPPT voltage range: 120-500Vdc
Battery voltage range: 40-60Vdc
Maximum output power - 4200W
Charge current range of solar energy (settable): 0-60A
11Charge short-circuit protection - Blown fuse
Wiring protection - Inverse wiring protection
Weight - 10.9kg